Abstract

Active power filter (APF) performance is entirely dependent on capacitor voltage. DC voltage optimizationis one of the key aspects in harmonics compensation. This paper presents an experimental comparativestudy of new adaptive fuzzy controller (AFC) and proportional integral (PI) regulator, applied to regulatethe DC bus voltage of three phase shunt APF. The proposed AFC for APF, consist to adapt the output gainof this controller at every situation of the system as a function of the voltage error and its variation.The algorithm used to identify the reference currents is based on the Self Tuning Filter (STF). The firingpulses of the insulated-gate bipolar transistors (IGBTs) inverter are generated using a hysteresis currentcontroller; which is implemented on an analog card. Finally, the above study, under steady state andtransient conditions, is illustrated with signal-flow graphs and corresponding analysis. This study wasverified by experimental tests on hardware prototype based on dSPACE-1104

چكيده

عملكرد فيلترهاي فعال قدرت كاملا وابسته به ولتاژ خازن است. يكي از جنبه هاي كليدي در حذف هارمونيك ها˓ بهينه سازي ولتا ژDC است. اين مقاله يك مقايسه عملي از كنترل كننده هاي فازي تطبيقي (AFC ) جديد ورگولاتورهاي انتگرالي- تناسبي(PI) كه براي تنظيم ولتاژباس DC فيلتر فعال قدرت موازي سه فاز بكار مي روند را ارائه ميدهد. AFC پيشنهاد داده شده براي APF ˓ گين خروجي اين كنترلر را در هر وضيعتي كه سيستم قرار دارد بعنوان يك تايع از خطاي ولتاژ و تغييرات آن تطبيق ميدهد. از الگوريتم براي استخراج جريان هاي مبنا بر اساس فيلتر خود تنظيم (STF) استفاده ميشود. پالس هاي آتش براي ترانزيستور هاي دو قطبي با گيت عايق شده (IGBTs) اينورتر با استفاده از كنترل كننده جريان هيسترزيس توليد ميشوند كه اين عمل بر روي يك كارت آنالوگ انجام ميگيرد. در پايان ˓بررسي بالا تحت شرايط حالت گذرا و پايدار با نمودار گذر سيگنال توضيح و بر طبق آن تحليل ميشود اين مطالعه با انجام آزمايش هاي تجربي بر روي نمونه سخت افزاري بر مبناي dSPACE-1104 تاييد شده است.

1-مقدمه

درسال هاي اخيربا پيشرفت تكنولوژي نيمه هادي هاي قدرت، وسايل بر پايه الكترونيك قدرت مانند جبران سازهاي استاتيكي توان راكتيو˓ درايو هاي با سرعت قابل تنطيم بطور گسترده اي در كاربردهاي مختلف استفاده ميشوند.

بخاطر طبيعت غير خطي V-I اين تجهيزات جرياني كه از منابع AC ميكشند حاوي هارمونيك و توان راكتيو است كه اين جريان هارمونيكي كشيده بوسيله بارهاي غير خطي در نقطه اتصال مشترك(PCC)، شكل موج ولتاژ را دچار اغتشاش ميكند و باعث ايجاد ولتاژهاي هارمونيكي ميشود...

سال


2208
پياده سازي كنترل كننده هاي فازي تطبيقي وPI براي تنظيم ولتاژ باس DC فيلتر هاي فعال قدرت موازي

پياده سازي كنترل كننده هاي فازي تطبيقي وPI براي تنظيم ولتاژ باس DC فيلتر هاي فعال قدرت موازي

دانلود رايگان اصل مقاله انگليسي

تعداد صفحات انگليسي:7

تعداد صفحات فارسي به فرمت ورد:20

سال انتشار:2015

ناشر:elsevier

Abstract

Active power filter (APF) performance is entirely dependent on capacitor voltage. DC voltage optimizationis one of the key aspects in harmonics compensation. This paper presents an experimental comparativestudy of new adaptive fuzzy controller (AFC) and proportional integral (PI) regulator, applied to regulatethe DC bus voltage of three phase shunt APF. The proposed AFC for APF, consist to adapt the output gainof this controller at every situation of the system as a function of the voltage error and its variation.The algorithm used to identify the reference currents is based on the Self Tuning Filter (STF). The firingpulses of the insulated-gate bipolar transistors (IGBTs) inverter are generated using a hysteresis currentcontroller; which is implemented on an analog card. Finally, the above study, under steady state andtransient conditions, is illustrated with signal-flow graphs and corresponding analysis. This study wasverified by experimental tests on hardware prototype based on dSPACE-1104

چكيده

عملكرد فيلترهاي فعال قدرت كاملا وابسته به ولتاژ خازن است. يكي از جنبه هاي كليدي در حذف هارمونيك ها˓ بهينه سازي ولتا ژDC است. اين مقاله يك مقايسه عملي از كنترل كننده هاي فازي تطبيقي (AFC ) جديد ورگولاتورهاي انتگرالي- تناسبي(PI) كه براي تنظيم ولتاژباس DC فيلتر فعال قدرت موازي سه فاز بكار مي روند را ارائه ميدهد. AFC پيشنهاد داده شده براي APF ˓ گين خروجي اين كنترلر را در هر وضيعتي كه سيستم قرار دارد بعنوان يك تايع از خطاي ولتاژ و تغييرات آن تطبيق ميدهد. از الگوريتم براي استخراج جريان هاي مبنا بر اساس فيلتر خود تنظيم (STF) استفاده ميشود. پالس هاي آتش براي ترانزيستور هاي دو قطبي با گيت عايق شده (IGBTs) اينورتر با استفاده از كنترل كننده جريان هيسترزيس توليد ميشوند كه اين عمل بر روي يك كارت آنالوگ انجام ميگيرد. در پايان ˓بررسي بالا تحت شرايط حالت گذرا و پايدار با نمودار گذر سيگنال توضيح و بر طبق آن تحليل ميشود اين مطالعه با انجام آزمايش هاي تجربي بر روي نمونه سخت افزاري بر مبناي dSPACE-1104 تاييد شده است.

1-مقدمه

درسال هاي اخيربا پيشرفت تكنولوژي نيمه هادي هاي قدرت، وسايل بر پايه الكترونيك قدرت مانند جبران سازهاي استاتيكي توان راكتيو˓ درايو هاي با سرعت قابل تنطيم بطور گسترده اي در كاربردهاي مختلف استفاده ميشوند.

بخاطر طبيعت غير خطي V-I اين تجهيزات جرياني كه از منابع AC ميكشند حاوي هارمونيك و توان راكتيو است كه اين جريان هارمونيكي كشيده بوسيله بارهاي غير خطي در نقطه اتصال مشترك(PCC)، شكل موج ولتاژ را دچار اغتشاش ميكند و باعث ايجاد ولتاژهاي هارمونيكي ميشود...

سال


2208
نظرات این مطلب

تعداد صفحات : 411

درباره ما
موضوعات
آمار سایت
  • کل مطالب : 4111
  • کل نظرات : 0
  • افراد آنلاین : 12
  • تعداد اعضا : 2
  • بازدید امروز : 324
  • بازدید کننده امروز : 1
  • باردید دیروز : 76
  • بازدید کننده دیروز : 0
  • گوگل امروز : 0
  • گوگل دیروز : 7
  • بازدید هفته : 654
  • بازدید ماه : 1377
  • بازدید سال : 12962
  • بازدید کلی : 582554
  • <
    پیوندهای روزانه
    آرشیو
    اطلاعات کاربری
    نام کاربری :
    رمز عبور :
  • فراموشی رمز عبور؟
  • خبر نامه


    معرفی وبلاگ به یک دوست


    ایمیل شما :

    ایمیل دوست شما :



    کدهای اختصاصی